Graphtec gl220 pdf merge

Graphtec plotting instruments are used across a wide spectrum of industries from cad applications to sign making. View and download graphtec midi logger gl220 user manual online. Suitable for voltage, temperature, humidity, pulse, and logic signals. The name graphtec is abbreviated from graphics technology, which just about sums us up really. Graphtec gl200 compare gl200 midi logger mainframe data logger with 3. Maintenance or repair by unauthorized service personnel is to be strictly avoided. General discussion pertaining to the graphtec cutting plotters. The captured data can be stored in gbd graphtec binary data or csv file format.

Graphtec acadp20 acdc power adaptor for gl240gl220gl200. Graphtec gl840 data logger data loggers instrumart. Support period for legacy models in pdf 83 kb download now. Software can also be used with the graphtec gl800 simultaneously with the gl220. Onced you have downloaded and installed both items, proceed to opening the gl220820 aps software. Graphtec gl240 is a thirdgeneration data logger product with exceptional priceperformance.

Graphtec ce600060 working from one pc not from another. Graphtec data logger recorder gl100,gl220,gl240,gl820,gl840,gl900,gl7000,mt100 tags. This is the default screen when the gl220 is turned on, and both waveforms and digital values are displayed. The gl220 midi logger is a compact, lightweight, multichannel data logger that provides 10 analogue measurement channels, along with four channels of each discrete logic and pulse inputs, also supporting one external trigger input and four alarm outputs. Configuring channels using graphtec gl series instruments. It sends the cutting object to the graphtec cutting plotter, and can also control the plotter. Control gl220, realtime data capture, replay data, data format conversion.

The graphtec gl240 midi logger has 10 channels, each isolated from each other and supports voltage, temperature, humidity, pulse and logic inputs. This is a step up in capacity and advanced cutting features from the silhouette cameo, with a touchscreen easy interface, the ability to cut 20 rolls of heat transfer vinyl, and completely automated contourcutting of printed labels and stickers, with arms 7. When an empty battery is charged in other recorder gl220820900 units, the. All s regarding this manual belong to graphtec corporation.

The graphtec gl840 data logger is a standalone multichannel data logger with isolated universal input. Graphtec gl220 data logger technical knowledge on the. Graphtec web site click this button to access the graphtec web site. In this multimedia presentation well demonstrate how to configure channels using your gl220, gl820, gl900 or mt100 series data acquisition system. Voltage, current, temperature, humidity and logic io. Cdrom user s manual pdf format, ap plication software 1 piece quick start guide 1 copy options and accessories item model number remarks logic alarm cable b5 2 m long no clip on end of cable dc drive cable b514 2 m long no clip on end of cable battery pack b517 1 piece 7. Graphtec cutting plotter discussion uscutter forum. It has all the features of a data logger, together with quality and high performance. The gl220 saves measured data directly to usb memory sticks. Instruments usb driver control software converters graphtec binary to text format windows vista x32 and x64 edition windows 7 8 8.

Portable, hand held, battery operated 10 channel data logger. It has 10 isolated channels each with multifunction input. Gl200um2519370 ii to ensure safety this service manual has been compiled for the purpose of facilitating repair and maintenance of the gl200 midi logger by graphtec service personnel and other persons who have undergone equivalent technical training. Refer to the users manual in the supplied cdrom for more information on the setting. Contains an isolated input system which ensures that signals are not corrupted by inputs to other channels.

Graphtec are a leading manufacturer of powerful yet easy to use imaging products for a wide variety of applications. Graphtec 10 channel data logger hire data loggers nz. In addition to accommodating numerous measurements, the gl840 includes many communications options and advanced functions making it an incredibly versatile data acquisition instrument for a wide array of applications. Sensors are connected via rear mounted screw terminals. Graphtec gl220 humidity, temperature, voltage data logger. Graphtec america gl220 data loggers recorders plotters. A fully charged battery allows an operating time of 57 hours depending upon data logging configuration.

The new graphtec celite 50 20 vinyl cutter is now available. Graphtec midi logger gl220 user manual pdf download. The graphtec gl220 10 channel comprehensive portable midi logger accepts voltage, temperature, humidity, pulse and logic signals. The gl220 channel count can now be increased by connecting up to 10 gl220 to a personal computer running the gl220 control software. If you need to move large data files to your pc then the gl220 can emulate an external usb drive for quick data transfer. The isolated input system ensures that signals are not interfered with by sensors connected to other.

View online or download graphtec midi logger gl220 user manual. By combining the four main requirements, searchmove data in various ways. Download and install both the usb driver and the aps software from our web site. When the gl220gl820gl200agl800 is connected to a pc, data can be exported to a pc. The gl220 can be controlled by a pc if connected by usb cable, allowing transfer of data to a pc in realtime. Gl220, gl240, gl820, gl840 series, gl900 series, gl7000 series. Graphtec fc8600 premium class is a powerful tool for any industry professional and offers up to 600 grams of force and up to 49 feet tracking. Configuration and channel setup via usb or ethernet. Do not place coffee cups or other receptacles containing fluid on the gl220. Downloading the graphtec studio for windows os graphtec. Gl220 gl820 pelican 1450 case with custom foam inserts protect your gl investment with ip67 rated case protection. The graphtec midi logger gl220 is claimed to set a new benchmark in generalpurpose data loggers. Gl7000, gl980, gl2000, gl240, gl840, gl220 and gl820.

Builtin 2 gb flash memory for reliable long term measurement. Channeltochannel isolation means wiring errors or overloaded channels do not affect neighbouring channels. Downloading the graphtec studio for windows os this software is application software for creating original design on the windows. Gl220 main unit specifications item description number of analog input channels 10 ch external inputoutput input9 trigger or sampling input 1 ch, logic or pulse input 4 ch output9 alarm output 4 ch sampling interval 10 ms to 1 h in 10ms to 50ms, voltage only and limited channel, external time scale 1 sec to 24 hour division trigger function. Refer to the usb driver installation manual for the installation procedure. With its color monitor and internal memory the gl220 is a compact, lightweight, multichannel data logger that provides 10 analog measurement channels. Graphtec fc9000100 42 rollfed vinyl cutter and plotter with stand and basket max. Measurements can be performed simultaneously or independently. Energy and buildings 149 2017 246259 contents lists available at sciencedirect energy. Memory sticks can be replaced during measurement without any data loss.

The quick start guide is to assist with the basic operations. The gl220 is supplied with software that provides excellent control over most gl series functions. Usb memory sticks can be replaced during measurement without data loss. File operation, converting data format to csv from gbd binary, merge multiple data files. Data logger graphtec gl220 gl240 gl820 gl840 gl100 gl900. Please refer to the users manual pdf in the cdrom for more. Despite its small footprint, the gl220 offers an isolated input system that ensures no channel is affected by different signals input. It also provides convenient data transfer and control from your pc to the gl220 as well as converting measured data into file formats that can be used with spreadsheet applications, data analysis applications, and other software programs. For gl220 download software click here for gl820 d ownload software click here. Graphtec gl220 was connected in a feedback loop with the heat.

Gl840wv 300vpp high voltage logger withstands voltage of 2300 vpp 1 min. Includes aps software, startup manual, ac power supply. Datalogger pelican 1450 case with form fitting custom foam inserts designed for the gl220 or gl820 data logger instruments and accessories. Graphtec gl220 10 channel portable midi logger with 4. Contains an insulated input system which ensures that signals are not corrupted by inputs to other channels. Gl840m 60vp p thermocouplevoltage logger withstands voltage of 350 vpp 1 min. The graphtec gl840 midi data logger has 20 channels, with option to expand to 200 channels, each isolated from each other and supports voltage, temperature, humidity, pulse and logic inputs. The gl220 multitype inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature humidity and voltage. Graphtec midi logger gl series graphtec gl200 gl200 gl. Manual connection mode and automatic connection mode ver. Gl220um2519370 ii to ensure safety this service manual has been compiled for the purpose of facilitating repair and maintenance of the gl220 midi logger by graphtec service personnel and other persons who have undergone equivalent technical training. Marking the evolution of the gl220 to the onedataloggerperperson stage. Graphtec gl220 data logger 10 isolated analogue channels, each with multifunction input maximum sampling rate up to 10ms large easy to read 4. Graphtec cutting plotter support requests uscutter forum.

Internal battery pack option b569 the gl240 supports a battery pack option b569 that allows operation independent of ac power. Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. Its a 10 analog channel device augmented by four discrete inputs and outputs. Contents thank you for choosing graphtec midi logger gl240. Its discrete inputs can be configured as a group to be either logic inputs or pulse inputs. Voltage 20mv to 50v, thermocouples k,e,j,t,n,r,s,t,b,w and 420ma signals via external shunt resistor.

261 702 684 817 129 1001 583 1502 1129 839 59 1518 1153 157 204 498 193 692 565 270 1280 1192 377 10 13 459 114 608 406 270 435 660 148 176 1157 51 6 726 676 102 736 830 1056 285 500